VANTAGE CONTROLS
Vantage Communicating Thermostat
VC-CC-STAT
Backorder
The Vantage CC-STAT Communicating Thermostat is a multi-function HVAC thermostat that delivers comfort and energy efficiency with full InFusion integration. It can operate as a stand-alone thermostat or, when combined with a thermostat interface station, control most residential HVAC systems — including single-stage, heat pump, multi-stage, and humidifier/dehumidifier systems. An on-board relative humidity sensor and direct connection of indoor or outdoor sensors let temperatures and setpoints be viewed on the thermostat or any Vantage touchscreen.
| Model | CC-STAT |
| Thermostat Dimensions | 4.9375" H x 6" W x 1.3125" D (125.4mm H x 98.4mm W x 49.2mm D) |
| Weight | 15 oz (.425kg) |
| Power Draw Maximum | 86.4 mA rms – with 24 VAC input voltage and backlight ON |
| Power Draw Typical | 21.6 mA rms – with 24 VAC input voltage and backlight OFF |
| Power Input | 18-30 Vac (24VAC nominal), 50/60Hz |
| Maximum Load Per Terminal | 1 amp |
| Maximum Load All Terminals | 2.5 amp |
| DC Power | 3.0 Volts DC (2 "AA" Alkaline batteries included) |
| Compatible Systems | Standard gas, oil, electric; Single stage/heat pump/multi-stage |
| Rated Output Current | 0.001 A to 1 A continuous per output with up to 5 A surge (half cycle) |
| Control Range | 45° to 99°F (7° to 32°C) |
| Display Range | 32° to 99°F (0° to 40°C) |
| Accuracy | ± 1°F (± .5°C) |
| Typical Control Accuracy | ± 1°F at 68°F / ± 0.5°C at 20°C |
| Storage Temperature | -30° to 140°F (-34.4° to 60°C) |
| Operating Humidity | 5% to 90% relative humidity |
| Operating Ambient Temperature | 32° to 120°F (0° to 48.9°C) |
| System Requirements | Each Vantage thermostat requires a thermostat interface, RadioLink or WireLink |
| System Compatibility | InFusion |
| Warranty | 5-year limited (Vantage) |
No downloads available for this product.